ultra low pressure
less than 10 bar operation and 99.5% rejection
For energy saving and high productivity
For an unbeatable quality permeate under ultra low pressure operating conditions these membranes elements are difficult to beat. A drinking water compliant membrane particularly suitable for:
- process pure water manufacture
- boiler feed water manufacture
- power station demin plant feed
- nitrate removal from drinking water supplies
- pure water production for laboratories
- pure water production for window cleaning
Key parameters
ULP operating data
Datasheets
Key parameters
- Maximum operating pressure 41.4 Bar
- Maximum operating temperature 45 ℃
- Maximum feed flow rate 17 m3/hour (8040) 3.6 m3/hour (4040)
- Maximum feed SDI 5.0
- Free chlorine tolerance <0.1 mg/l (de-chlorination essential)
- pH range (operation) 2-11
- pH range (short term cleaning) 1-11
ULP operating data
- Feed water TDS <1500 mg/l
- For operation between 6-12 Bar
- 99.5% salt rejection
- Standard test pressure 10.5 Bar
Datasheets
ULP Product range
4040 elements
Model | Active membrane area m2 | Permeate flow m3/day | Stable (minimum) salt rejection rate % |
ULP-4040MR-2 | 9.3 | 9.1 | 99.6 |
ULP-4040-2 | 7.9 | 8.3 | 99.5 |
9.3 | 10.2 | 99.5 |
4021 elements
Model |
Active membrane area m2 |
Permeate flow m3/day |
Stable (minimum) salt rejection rate % |
ULP-4021 |
3.3 |
3.6 |
99.2 (99.0) |
|
|
|
|
|
|
|
|
8040 elements
Model | Active membrane area m2 | Permeate flow m3/day | Stable (minimum) salt rejection rate % |
ULP-8040MR-2 | 40.9 | 39.7 | 99.6 |
ULP-8040-2 | 37.2 | 37.8 | 99.5 |
40.9 | 47.3 | 99.5 |